Regulatory Status:RUO
Alternative:OLR1; CLEC8A; SCARE1; Oxidized low-density lipoprotein receptor 1; C-type lectin domain family 8 member A; Lectin-like oxidized LDL receptor 1; Lectin-type oxidized LDL receptor 1
Regulatory Status:
Alternative:
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.15-10ng/mL
Sensitivity:
0.06ng/mL
Specificity:
This kit recognizes Human LOX1 in samples. No significant cross-reactivity or interference between Human LOX1 and analogues was observed.
Sample Type:
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Research Area:
Signal Transduction
Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX-1) is a protein encoded by the OLR1 gene. LOX-1 is a receptor protein which belongs to the C-type lectin superfamily. Its gene is regulated through the cyclic AMP signaling pathway. LOX-1 is the main receptor for oxidized LDL on endothelial cells, macrophages, smooth muscle cells, and other cell types. But minimally oxidized LDL is more readily recognized by the TLR4 receptor, and highly oxidized LDL is more readily recognized by the CD36 receptor. The protein binds, internalizes and degrades oxidized low-density lipoprotein.
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.
Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.62 | 0.31 | 0.15 | 0 |
OD | 2.34 | 1.88 | 1.37 | 1.11 | 0.79 | 0.43 | 0.23 | 0.08 |
Corrected OD | 2.26 | 1.8 | 1.29 | 1.03 | 0.71 | 0.35 | 0.15 | - |
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
The recovery of Human LOX1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
Samples were spiked with high concentrations of Human LOX1 and diluted with Universal Diluent to produce samples with values within the range of the assay.
Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 89-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |