Mouse Transcription initiation factor TFIID subunit 12 (TAF12) ELISA Kit KB-E12018M

Regulatory Status:RUO

Alternative:TAF2J; TAFII20; TATA Box Binding Protein Associated Factor 12; Transcription initiation factor TFIID 20/15 kDa subunits

Regulatory Status:

RUO

Alternative:

TAF2J; TAFII20; TATA Box Binding Protein Associated Factor 12; Transcription initiation factor TFIID 20/15 kDa subunits

Detection Method:

ELISA

Assay Type:

Sandwich

Detection Range:

0.156-10ng/mL

Sensitivity:

0.076ng/mL

Specificity:

This kit recognizes Mouse TAF12 in samples. No significant cross-reactivity or interference between Mouse TAF12 and analogues was observed.

Sample Type:

Tissue homogenates and other biological fluids.

Research Area:

Signal Transduction

| TAF12


Transcription initiation factor TFIID subunit 12 is a protein that is encoded by the TAF12 gene.Control of transcription by RNA polymerase II involves the basal transcription machinery, which is a collection of Proteins. These Proteins with RNA polymerase II, assemble into complexes that are modulated by transactivator Proteins that bind to cis-regulatory elements located adjacent to the transcription start site. Some modulators interact directly with the basal complex, whereas others may act as bridging Proteins linking transactivators to the basal transcription factors.

 

| Typical data


As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.


  

Concentration (ng/mL)1052.51.250.6250.3120.1560
OD2.11.460.950.610.40.280.220.08
Corrected OD2.021.380.870.530.320.20.14-

 





| Repeatability


Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%

 

| Recovery


The recovery of Mouse TAF12 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.


 

Sample TypeRange(%)Average Recovery(%)
Tissue Homogenates(n=8)90-105101






 

| Linearity


Samples were spiked with high concentrations of Mouse TAF12 and diluted with Universal Diluent to produce samples with values within the range of the assay.


 



Tissue Homogenates(n=4)
1 : 2Range (%)88-96
Average (%)93
1 : 4Range (%)87-108
Average (%)99








124.jpg

Inquiry

Scan the qr codeclose