Rat Lymphotoxin Beta (LTb) ELISA Kit KB-E22165R

Regulatory Status:RUO

Alternative:LT-B; p33; TNFC; TNF-C; TNFSF3; Tumor necrosis factor ligand superfamily member 3; Tumor Necrosis Factor C

Alternative:

LT-B; p33; TNFC; TNF-C; TNFSF3; Tumor necrosis factor ligand superfamily member 3; Tumor Necrosis Factor C

Detection Method:

ELISA

Assay Type:

Sandwich

Detection Range:

15.62-1000pg/mL

Sensitivity:

6.21pg/mL

Specificity:

This kit recognizes Rat LTb in samples. No significant cross-reactivity or interference between Rat LTb and analogues was observed.

Sample Type:

Serum, plasma and other biological fluids.

Research Area:

Cancer


| LTb


Lymphotoxin-beta (LT-beta) formerly known as tumor necrosis factor C (TNF-C) is a protein that is encoded by the LTB gene.Lymphotoxin beta is a type II membrane protein of the TNF family. It anchors lymphotoxin-alpha to the cell surface through heterotrimer formation. The predominant form on the lymphocyte surface is the lymphotoxin-alpha 1/beta 2 complex (e.g. 1 molecule alpha/2 molecules beta) and this complex is the primary ligand for the lymphotoxin-beta receptor. The minor complex is lymphotoxin-alpha 2/beta 1. LTB is an inducer of the inflammatory response system and involved in normal development of lymphoid tissue.

 

| Typical data


As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.


  

Concentration (pg/mL)100050025012562.531.2515.620
OD2.471.40.770.460.320.220.20.08
Corrected OD2.391.320.690.380.240.140.12-

 






| Repeatability


Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%

 

| Recovery


The recovery of Rat LTb spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.


 

Sample TypeRange(%)Average Recovery(%)
Serum(n=8)84-10296
Plasma(n=8)92-105101







 

| Linearity


Samples were spiked with high concentrations of Rat LTb and diluted with Universal Diluent to produce samples with values within the range of the assay.


 



Serum(n=4)Plasma(n=4)
1 : 2Range (%)85-9588-96
Average (%)9193
1 : 4Range (%)89-10387-108
Average (%)9499